Home    15000 Series-LOX/LIN Cryogenic ASP    15001A KDON-1500Y/1500(51.41TPD LOX+45TPD GAN) Liquid Oxygen/Liquid Nitrogen Air Separation Plant

15001A KDON-1500Y/1500(51.41TPD LOX+45TPD GAN) Liquid Oxygen/Liquid Nitrogen Air Separation Plant

Tag No.:15001A

Model:KDON-1500Y/1500(51.41TPD LOX+45TPD GAN)

Name:Liquid Oxygen/Liquid Nitrogen Air Separation Plant

 

General performance and utilities consumption:

1

General performance

 

Description

Output

Purity

Pressure ex cold box

Mode 1

(Design mode, Max LOX)

 

 

 

Liquid oxygen (LOX)

1500Nm³/hr

(2142Kg/hr, 1876L/hr)

99.6% O2

0.05MPa G

Gas nitrogen (GAN)

1500Nm³/hr

(1876Kg/hr)

10 ppm O2

0.01MPa G

Mode 2:

(Auxiliary mode, Max LIN)

 

 

 

Liquid oxygen (LOX)

200Nm³/hr

(285Kg/hr, 250L/hr)

99.6% O2

0.05MPa G

Liquid nitrogen (LIN)

1450Nm³/hr

(1813Kg/hr, 2240L/hr)

10 ppm O2

0.01MPa G

Note:

1. The output flow Nm³ is same to input air flow Nm³ after air purifier. Normally Nm³ means volume under standard conditions (0 °C, 0.1013 MPa A). If the input dry air flow after purifier is supplied by buyer in Sm³ (20 °C, 0.1013 MPa A), the output shall be adjusted to Sm³ technically and accordingly.

2. The performance is based on design basis of clause 1 in this technical annex.

3. Standard industrial performance tolerance: Output: + 4%      Purity: 0%

4. The output flow is based on flow ex cold box. The vaporization loss transfer pipe from cold box to tank, tank vaporization loss, filling vaporization loss should be all considered and calculated as ASP output according to China GB standard.

5. Reserve LIN nozzle at cold box.

2

Electricity requirement

 

SN

Equipment

Installed power/Shaft power, KW

1

Self-cleaning air filter

0.2

2

Main air compressor

1102/960

3

Booster air compressor

1102/880

4

Air pre-cooler

50/45

5

Air chiller

45/35

6

Air purifier

150average 50

7

Turbine expander

 

 

Oil pump

5/3

 

Oil heater

5/0

8

Control system

5

9

Total installed power

2419.2

10

Total shaft power(tentative)

1943.2

11

Standard industrial power consumption tolerance: +4%

3

Recycle cooling water requirement

 

SN

Equipment

Recycle quantity, T/hr

1

Main air compressor

120

2

Booster air compressor

100

3

Air pre-cooler

30

4

Air chiller

15

5

Turbine expander

50+30

6

Total

345

4

Instrument air

 

 

Flow

~200Nm³/hr

Note: To be supplied by user during start up and stop. ASP shall supply by itself during normal running.

5

Cold box defrosting cycle

2 years

 

For more details, please feel free to contact us by email to sales@wintekgroup.com

 