21008A H-250×4 Hydrogen Generator
Tag No.:21008A
Model:H-250×4
Name:Hydrogen Generator
1. General performance and utilities/consumables consumption
1.1 |
General performance |
||||||||||
|
Description |
Output |
Purity |
Pressure |
Temperature |
Dew Point |
|||||
Gas hydrogen |
≥250Nm³/hr×4 |
≥99.999% H2 |
1.6MPa G |
30~40°C |
≤-60°C |
||||||
Gas oxygen |
≥125Nm³/hr×4 |
≥99.5% O2 |
1.6MPa G |
30~40°C |
≤-60°C |
||||||
Note: 2.1.1The output flow Nm³ is volume under normal conditions (0°C, 0.1013 MPa A). 2.1.2 The performance is based on design basis of clause 1 in this technical annex. 2.1.3 The output flow of the hydrogen/oxygen is adjustable between 30~100% of total installed power. |
|||||||||||
1.2 |
Electricity requirement |
||||||||||
|
SN |
Equipment |
Installed power/Shaft power, KW High Voltage |
Installed power/Shaft power, KW Middle Voltage |
|||||||
1 |
Rectifier cabinet (Water electrolyzer) |
7000/4400~4600 |
|
||||||||
2 |
Lye pump |
|
5.5×2×2 |
||||||||
3 |
Feed water pump |
|
7.5×2 |
||||||||
4 |
De-oxygen tower |
|
20×2 |
||||||||
5 |
Hydrogen dryer heater |
|
50×2 |
||||||||
6 |
De-hydrogen tower |
|
20 |
||||||||
7 |
Oxygen dryer heater |
|
50 |
||||||||
8 |
Instrumentation control system |
|
5 |
||||||||
9 |
Demineralized water machine |
|
10×2 |
||||||||
10 |
Gas hydrogen compressor |
|
(45+3+1+1.1) ×4 |
||||||||
11 |
Gas oxygen compressor |
|
(45+3+1+1.1) ×2 |
||||||||
12 |
Water cooling system |
|
90 |
||||||||
13 |
Water chiller |
|
128.2 |
||||||||
14 |
Chilled water recycle pump |
|
15 |
||||||||
15 |
Instrumental air system |
|
6.5 |
||||||||
|
Total installed power |
~7802.3 |
|||||||||
|
Tentative total consumption power (Based on shaft power) |
~5402.3 |
|||||||||
|
Note: Standard industrial power consumption tolerance: + 4% |
||||||||||
1.3 |
Recycle cooling water requirement |
||||||||||
|
SN |
Equipment |
Recycle quantity T/hr |
||||||||
1 |
Gas liquid separator unit |
76.5×2 |
|||||||||
2 |
Gas hydrogen compressor |
5×4 |
|||||||||
3 |
Gas oxygen compressor |
5×2 |
|||||||||
4 |
Water chiller |
67 |
|||||||||
|
Total |
250 |
|||||||||
1.4 |
Chilled water |
||||||||||
|
SN |
Equipment |
Recycle quantity T/hr |
||||||||
1 |
Rectifier cabinet (Water electrolyzer) |
|
|||||||||
2 |
Hydrogen purification unit |
12×2 |
|||||||||
3 |
Oxygen purification unit |
8 |
|||||||||
|
Total |
32+ |
|||||||||
1.5 |
Instrument air |
||||||||||
|
Flow |
~25Nm³/hr |
|||||||||
1.6 |
Gas nitrogen |
||||||||||
|
Quantity |
200Nm³ |
|||||||||
1.7 |
Demineralized water |
||||||||||
|
Flow |
1000L/hr |
|||||||||
1.8 |
Chemicals |
||||||||||
|
KOH (Potash Hydroxide) |
3500kg |
|||||||||
V2O5 |
20 kg |
||||||||||
1.9 |
Lubrication oil |
||||||||||
|
1 |
Gas hydrogen compressor |
Anti-wear hydraulic oil, 50Kg×4 |
||||||||
2 |
Gas oxygen compressor |
GSGE-O2 (for oxygen, nitrogen trifluoride, and fluorine), 50Kg×2 |
|||||||||
1.10 |
Refrigerant |
||||||||||
|
1 |
Water chiller |
160kg |
||||||||
1.11 |
Refrigerant oil |
||||||||||
|
1 |
Water chiller |
16L |
For more details, please feel free to contact us by email to sales@wintekgroup.com
Key Words: Hydrogen Generator,Water Electrolyzer,Water Electrolysis Hydrogen Production Equipment